Programmable TPI Control Thermostat --- TH-2013

































                      1. Operate power: 2 xAA1.5 Vdc Alkaline. Ba. ery low protection in-built
                      2. Output : Volt-free contact, rating 16Amp / 250 ac.
                      3. Output format: Selectable to users.
                        a. ON/OFF control to the required temperature setpoint.
                        b. Proportional I tegral output control to the required temperature setpoint.
                      4. Temperature indication: Celsius
                      5. Temperature display range: 0~50°C, Resolution 0.1°C Accu acy ±0.2°C.
                      6. Temperature control range: 5~45°C, Resolution 0.2°C
                      7. In-build temperature calibration: - 4.0°C  o 4.0°C, 0.2°C/Step.
                      8. Switching differential (H steresis): 4 selections----- 0.5/1.0/2.0/4.0 °C
                      9. Programming format: 7d, 4 program-period/day.
                      10. Program resolution: 10 minu es.
                      11. COPY function p ovided in programming format.
                      12. Program override function
                        a. Temporary override (Manual mode)
                        b. Vacation mode, hold  emperature up to 99 days
                      13. Able to operate in both Heating or Cooling ---- Selec able to users.
                      14. Stand-by mode: Manually turn on/off thermostat’s operation
                      15. Anti freezing protection: 5.0°C if  emperature drops below.
                      16.Temperature sensor: NTC 10K 25°C.
                      17.Temperature control through Internal or External temperature sensor is
                      selectable to  users.
                      18.Speical features included in thermostat :
                        a. Anti-seizing--Build-in, Au omatic. Thermo tat will turn on its output for
                          1 minute   once every week.
                        b. Lock mode--Prevent thermostat’s settings  om being tampered.
                        c. Operation time ecording--Automatic self d fault to “0” aer the clock was
                           reset / adjusted.
                        d. Day-light saving--Build-in, Automatic