Page 217 - 2020DM-1210
P. 217

Central Heating Programmer ( Time switch) 1~2 Channel
               TH-0472-2   240 Vac-operate & TH-0472-3 24 Vac-operate

































               Features:   1. Operate power: 1) 200~240 Vac 50/60HZ (TH-0472-2)
                                            2) 22~ 30 Vac 50/60HZ (TH-0472-3)
                          2. Output format: Voltage-free contact, Ra�ng 250 Vac 3(1) A
                          3. Circuitry power consump�on : 8VA /250 Vac
                          4. Programming format:
                          a. 7D/5+2D/Daily(24H) programming format, selectable to users.
                          b. 3 On/Off programs per day in each channel and is adjustable to users.
                          5. Clock format: 24 Hour or 12H (AM/PM) by default.
                          6. Each channel independently programmable.
                          7. Programming override:
                            a. BOOST func�on: Manually extending programmer’s opera�on or 1 to 3 hours.
                            b. ADV func�on: Reverse On/Off output status, un�l next opp ite setpoint.
                            c. HOLIDAY: Pre- scheduled to set programmer’s opera�on to  he longest 60
                            days in advance.
                          8. Programming resolu�on: 10 minutes
                          9. Backlight: Blue, 10-seconds Auto or Constant ON is selectable to users default
                            constant ON.
                          10. Daylight saving: Dura�on spans from the year A.C. 2005 to  099. Default upon
                            produc�on, not selectable to users
                          11. Non-vola�le memory (EEPROM) for retaining the programming
                          12. Lithium 3V CR 2032 for keep real �me cloc
                          13. For use in Pumped/Gravity system is selectable to users.
                          14. Dimension: 125x 89x 35 mm
                          15. Transparent P.C, terminal covers included on the Wiring back plate to
                            prevent the main from accidentally being touched.
                          16. Orange and Yellow LED indicators to separately indicate the ON/OFF status
                            for each channel.